Tile-Retro™ Anchor – Specs
Technical Specifications
Device
2 D-ring Permanent Roof Anchor
Fall Protection Rating
Fall Arrest and Fall Restraint
Service Load Angle 0-30 Degrees
Fall Arrest
Service Load Angle 30+ Degrees
Fall Restraint
Structure Attachment – Wood
Wood Framed Structure
Structure Attachment – Steel
24 gauge minimum metal decking with SAS engineering
Minimum Breaking
5,000 pounds
Minimum Tensile
5,000 pounds
Material – Strapping
20 gauge 430 Stainless Steel
Material – D-rings
Stamped Dacromet or yellow zinc plated steel
Flashing
Butyl flashing for waterproofing 2 @ 4″
Maximum User Weight
340 pounds including tools and equipment
Hardware
3-1/4″ Stainless steel nails
OSHA Standard
1926:502 and 1910.66
ANSI Standard
Z359.1-07 and A10.32-2012
Canadian 3rd Party
Certified by L’Ordre des Ingenierus du Quebec